|T000039, K11 Tracer
Compound Image

T000039

K11 Tracer


  • Properties

    Store at:

    -80 °C

    Absorption:

    450 nm

    Emission:

    590 nm
  • References

    Contributing Lab:

    Promega Corp., Madison

    Vendor:

  • Experimental

    Assay window 3.52
    \(Z'\) 0.76
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    220 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    51 nM
    displacement curve
    raw data

    Comment: ACVR1-NLuc

    Reference: source

    Assay window 4.3
    \(Z'\) 0.69
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    327 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    33 nM
    displacement curve
    raw data

    Comment: ACVR1(G328V)

    Reference: source

    Assay window 3.62
    \(Z'\) 0.75
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    520 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    129 nM
    displacement curve
    raw data

    Comment: ACVR1(G356D)-NLuc

    Reference: source

    Assay window 3.79
    \(Z'\) 0.81
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    402 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    51 nM
    displacement curve
    raw data

    Comment: ACVR1(Q207D)

    Reference: source

    Assay window 3.59
    \(Z'\) 0.75
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    388 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    41 nM
    displacement curve
    raw data

    Comment: ACVR1(R206H)-NLuc

    Reference: source

    Assay window 3.31
    \(Z'\) 0.88
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    184 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    378 nM
    displacement curve
    raw data

    Comment: ACVRL1-NLuc

    Reference: source

    Assay window 2.25
    \(Z'\) 0.75
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    252 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    113 nM
    displacement curve
    raw data

    Comment: BMPR1A-NLuc

    Reference: source

    Assay window 3.09
    \(Z'\) 0.75
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    231 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    34 nM
    displacement curve
    raw data

    Comment: NLuc-CDKL1

    Reference: source

    Assay window 10.69
    \(Z'\) 0.85
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    387 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    5 nM
    displacement curve
    raw data

    Comment: NLuc-CDKL2

    Reference: source

    Assay window 7.81
    \(Z'\) 0.84
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    196 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    5 nM
    displacement curve
    raw data

    Comment: NLuc-CDKL3

    Reference: source

    Assay window 7.81
    \(Z'\) 0.76
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    303 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    2 nM
    displacement curve
    raw data

    Comment: NLuc-CDKL5

    Reference: source

    Assay window 2.99
    \(Z'\) 0.83
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    267 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    122 nM
    displacement curve
    raw data

    Comment: EPHA3-NLuc

    Reference: source

    Assay window 2.13
    \(Z'\) 0.87
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    33 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    524 nM
    displacement curve
    raw data

    Comment: MAP2K6-NLuc

    Reference: source

    Assay window 2.17
    \(Z'\) 0.81
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    105 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    8 µM
    displacement curve
    raw data

    Comment: NLuc-NRK

    Reference: source

    Assay window 3.43
    \(Z'\) 0.94
    CP agreement yes
    Tracer titration

    \(K_\mathrm{D}^{\,\mathrm{app}}\):

    178 nM
    titration curve
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    \(\mathrm{EC}_{50}\):

    180 nM
    displacement curve
    raw data

    Comment: TGFBR2-NLuc

    Reference: source