|T000038, K8 Tracer
Compound Image

T000038

K8 Tracer


  • Properties

    Store at:

    -80 °C

    Absorption:

    450 nm

    Emission:

    590 nm
  • References

    Contributing Lab:

    Promega Corp., Madison

    Vendor:

  • Experimental

    : 2.84

    Z’: 0.85

    : yes

    Tracer titration

    KDapp:

    140 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    ABT-702

    EC50:

    5 nM
    raw data

    Comment: ADK-NLuc

    Reference: source

    : 2.23

    Z’: 0.87

    : yes

    Tracer titration

    KDapp:

    21 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AST-487

    EC50:

    13 nM
    raw data

    Comment: NLuc-CDK19 + CycC

    Reference: source

    : 2.52

    Z’: 0.9

    : yes

    Tracer titration

    KDapp:

    22 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AST-487

    EC50:

    38 nM
    raw data

    Comment: NLuc-CDK8 + CycC

    Reference: source

    : 6.73

    Z’: 0.74

    : yes

    Tracer titration

    KDapp:

    43 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    EC50:

    12 nM
    raw data

    Comment: NLuc-CDK9 + CycK

    Reference: source

    : 4.02

    Z’: 0.79

    : yes

    Tracer titration

    KDapp:

    69 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    Dinaciclib

    EC50:

    16 nM
    raw data

    Comment: NLuc-CDK9 + CycT1

    Reference: source

    : 3.21

    Z’: 0.86

    : yes

    Tracer titration

    KDapp:

    72 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    CEP-701

    EC50:

    757 nM
    raw data

    Comment: NLuc-ICK

    : 5.14

    Z’: 0.8

    : yes

    Tracer titration

    KDapp:

    124 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AZD-5438

    EC50:

    1 µM
    raw data

    Comment: NLuc-CSNK1D

    Reference: source

    : 2.54

    Z’: 0.85

    : yes

    Tracer titration

    KDapp:

    154 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    AZD-5438

    EC50:

    4 µM
    raw data

    Comment: NLuc-CSNK1E

    Reference: source

    : 3.38

    Z’: 0.64

    : yes

    Tracer titration

    KDapp:

    94 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    CHIR-99021

    EC50:

    55 nM
    raw data

    Comment: NLuc-GSK3A

    Reference: source

    : 7.43

    Z’: 0.77

    : yes

    Tracer titration

    KDapp:

    94 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    CHIR-99021

    EC50:

    120 nM
    raw data

    Comment: NLuc-GSK3B

    Reference: source

    : 2.55

    Z’: 0.71

    : yes

    Tracer titration

    KDapp:

    78 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    CEP-701

    EC50:

    419 nM
    raw data

    Comment: KIT(V559D,T670I)-NLuc

    Reference: source

    : 2.63

    Z’: 0.75

    : yes

    Tracer titration

    KDapp:

    55 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    PBI-7210

    EC50:

    89 nM
    raw data

    Comment: PIKFYVE-NLuc

    Reference: source

    : 3.14

    Z’: 0.72

    : yes

    Tracer titration

    KDapp:

    117 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    PBI-7210

    EC50:

    99 nM
    raw data

    Comment: PIP4K2C-NLuc

    Reference: source

    : 2.5

    Z’: 0.74

    : yes

    Tracer titration

    KDapp:

    54 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    PBI-7210

    EC50:

    3 µM
    raw data

    Comment: NLuc-PIP5K1B

    Reference: source

    : 2.79

    Z’: 0.84

    : yes

    Tracer titration

    KDapp:

    72 nM
    ...
    raw data
    Tracer displacement
    i

    Compound used for displacement:

    APY-69

    EC50:

    972 nM
    raw data

    Comment: NLuc-RIPK1

    Reference: source